WBI412S01 converts AC input current into a load independent output DC 0-5(10)V, 1-5V. It has adopted electromagnetic isolation principle for real time measurement of AC current from electric net or electric circuit.

The product has certain advantages of total galvanic isolation between input/output, high accuracy, low drifting by temperature, and wide temperature bearable range, etc.


Product Detail

Product Tags

Product Description and Application

WBI412S01 converts AC input current into a load independent output DC 0-5(10)V, 1-5V. It has adopted electromagnetic isolation principle for real time measurement of AC current from electric net or electric circuit.

The product has certain advantages of total galvanic isolation between input/output, high accuracy, low drifting by temperature, and wide temperature bearable range, etc.

Product Dimensional Drawing (unit: mm)

Caution

Key Technical Data

Attribute

Value

Input

AC 0~5A......0~50A

Output

DC 0-5(10)V

Accuracy

0.5%

Frequency range

25Hz~5kHz

Output impedance(Output current)

5mA

Linear range

0~120% of nominal input

Responding time

300ms

Over load capacity

10 times of nominal input, for 5 seconds

Current consumption for static status

3mA

Auxiliary power

9.+12VDC/+24VDC

Isolation voltage (Input/Output)

2500Vdc, for 1 minute

Output ripple

<6mV

Drifting by temperature

150×10-6/℃

Ambient temperature

-10℃~+50℃

Mounting

DIN rail 35mm mount or screw mount

Caution

1.Pay attention to the auxiliary power information, especially the auxiliary power grade, and polarity, other wise will damage the product.
2.Pay attention to the wire connection; wrong terminal connection will cause malfunction of the product and even damage the product;
3.Don’t dismantle the product, and carry with care to avoiding bump and fall of the product;
If the product has been using under the environment with strong magnetic field interference, please pay attention to the shield of input wire, and the output signal wire should be as short as possible. For product intensive installation, the space between each product should not be smaller than 10mm.
Only use identified terminals.
4.There is no lightening strike prevention circuit design in this product. For out door and hazardous environment using, please add protective alternatives.
5.This product uses fire prevent ABS crust, its temperature withstand is only limited as +85℃, higher than this limitation will cause the product deformation. Please use and store carefully.


  • Previous:
  • Next:

  • Write your message here and send it to us